Sunday, July 13, 2014

Preparing Engine room for dry dock.

25 Important Points to Consider While Securing the Engine Room for Dry Docking

Once the vessel enters the dry dock for hull inspection, it is important that the ship’s engineer secure the ship’s propulsion plant and the engine room in the correct sequence to prevent any kind of damage or problem while restarting the plant once the dry docking of the vessel is finished.
Following points must be considered once the ship enters the dry dock and before emptying the water from the dock to rest the ship on the keel blocks:
1. Ensure all the tanks in the engine room are at required level as demanded by the chief officer to achieve required trim for docking.
Related reading :
Maintenance of small tanks in the ship’s engine room , List of some important tanks on shipList of fuel, diesel, and lube oil tanks on ships.
2. Shut down all the auxiliary engines except one for providing the required power
Related Reading:
Procedure for starting and stopping generatorsImportant signs indicating auxiliary engine needs overhaulingA step-by-step guide to overhauling generators on ships.
3. Isolate sequential start system for generators
Related Reading:
How to synchronize generators on ships?Important points to consider while carrying out alternator maintenance of ship’s generatorImportant points for major overhauling of ship’s generator
4. Shut steam to jacket cooling water system
drydock
Related Reading:
General Overview of Central Cooling System of Ships
5. Keep the jacket cooling water pump running  until the main engine is gradually cooled down
6. Transfer the main engine lube oil in the sump to lube oil settling tank by using purifier
mairne engine
Related Reading:
Ways to optimize lube oil usage on ships
7. Ensure all auxiliary engines are shut down except one diesel engine supplying enough power
8. Before shutting down all the auxiliary engines, ensure they are changed over to diesel oil
Related Reading:
Fuel oil change over procedure
9. The main engine should be changed over to diesel oil prior one hour of docking. If not, changeover to diesel oil with fuel oil service tank return valve open until line has been flushed with diesel oil
10. Shut down lube oil and fuel oil purifiers
11. Shut down deck machinery system and isolate it from main switchboard
Related Reading:
Safety Devices for Main Switch Board 
12. Shut down and isolate the auxiliary boiler. Allow it to cool naturally and once the pressure is below 1 bar, open the vent
Related Reading:
Shutdown procedure of boiler
13. Once the boiler is shut down, stop and isolate the feed water system and distillate tank
14. Circulate diesel oil in the boiler fuel pipeline system before shutting down the fuel oil pumps
15. Shut down the stern tube lube oil system and if required, drain the lube oil system back to stern tube storage tank
16. Shut down the accommodation air conditioning system and refrigeration plant until the shore supply is connected to the ship
Related Reading:
8 Common Problems Found in Ship’s Refrigeration System
17. Shut the steam to the alorifier and switch on the electrical heating system
18. Ask shore in-charge for water connection required for running air conditioning and refrigeration system
19. Isolate ship’s fire pump and connect the shore fire connection to ship’s fire line
Related Reading:
What is international shore connection?
20. Check the frequency, voltage and phase sequence of the shore power
21. Isolate emergency generator before connecting shore power
Related Reading:
Ways of Starting and Testing Emergency Generator 
22. Shut down the running generator leading to blackout for connecting shore power
23. Connect the shore power to emergency switchboard
Related Reading:
What is cold ironing?
24. Restart the jacket water pump for the generator until it is gradually cooled down to avoid thermal stresses. Once cooled, shut the pump
25. Secure the engine room fire fighting system including foam and CO2 fixed fire fighting system
Related Reading:
Mistakes not to make while handling CO2 Fire Fighting System
Inform the dry dock in- charge that engine room is ready for docking and dock water can be emptied.
Is there any other important points that should be added to the list? Let us know in the comments below.
For complete procedure of various dry dock operations for Engine Room Department, check out our ebook:
A Guide to Master Dry Dock Operations (For engine room department) is a downloadable ebook designed to help you understand the whole dry docking procedure is a step-by-step manner, right from the planning to sea trials.

No comments:

Post a Comment